RFEM 5 / RSTAB 8 | Adjusting Wind Load Distribution in

How can I control the wind load distribution on tower sides in the RF‑/TOWER Loading add-on module?


Answer:

A user-defined wind load distribution is not provided in the Eurocode. In order to implement a user-defined wind load distribution in the RF‑/TOWER Loading add-on module, this can only be done after conversion to DIN; for example, DIN 4131:1993‑11, Window "1.3 Wind Load – Part 1".

Then, you can select the user-defined distribution in Window "1.4 Wind Load – Part 2" and define it in the adjacent table.