Detailed Results on Member End Nodes for Member Loads Defined in Sections

Why are the intermediate results for some members exactly at the member end node in the result table of member internal forces?


Answer:

The result display of intermediate values is generally linked to the member division property. Also, member loads defined in sections in RFEM generate further intermediate results. For example, if a member load defined in sections is distributed from the member start to the member end, the intermediate results are obtained at the member end nodes.


Author

Andreas is responsible for the development of RSTAB, RFEM, and RWIND Simulation, as well as the membrane structure division. In addition, he coordinates quality assurance processes and provides technical support to customers.