Do I have an opportunity to consider cross-section reductions due to drilling or the like without having to remodel the cross-section in the SHAPE‑THIN program, for example?


Answer:

If the drilling holes are subject to a regular grid, they can be defined using built-up cross-sections (see Image 01).

Otherwise, there is still the possibility to reduce the cross-section in "Properties" (see Image 02). This results in a general reduction in the stiffness of the cross-section. Unfortunately, it is not possible to distinguish between the reductions in the compression and tension areas of the cross-section. This option is only available when remodeling the cross-section in the SHAPE‑THIN program or in some modules of the JOINTS family in the area of the connections.


Author

In Product Engineering, Bastian is responsible for development and quality assurance in timber structures and also plays an active role in customer support. His experience directly informs how he addresses practical issues.