This model demonstrates a robust beam-to-column-flange connection featuring an extended end plate. It includes structural enhancements like a haunch, beam and column stiffeners, and column web reinforcement. The connection is achieved with bolted joints, ensuring rigidity in the fixed beam construction. The continuous column design ensures stability and strength across the structure.
Beam to Column Flange Connection via Extended End Plate with Haunch and Stiffeners
| Number of Nodes | 4 |
| Number of Lines | 3 |
| Number of Members | 3 |
| Number of Surfaces | 0 |
| Number of Solids | 0 |
| Number of Load Cases | 0 |
| Number of Load Combinations | 0 |
| Number of Result Combinations | 0 |
| Total Weight | 0.114 tons |
| Dimensions (Metric) | 0.830 x 1.160 x 0.000 m |
| Dimensions (Imperial) | 2.72 x 3.81 x 0 feet |