Design check details in Timber Design showing shear resistance of sheathing-to-beam connectors for wood-frame shear wall per NDS 2024 with Table 4.3A nominal unit shear capacities.
Design check details in Timber Design showing shear resistance of sheathing-to-beam connectors for wood-frame shear wall per NDS 2024 with Table 4.3A nominal unit shear capacities.
2026-08-31
064590
  • RFEM 6

Shear Wall Design Check UL7100 per NDS 2024

Design check details in Timber Design showing shear resistance of sheathing-to-beam connectors for wood-frame shear wall per NDS 2024 with Table 4.3A nominal unit shear capacities.

The Design Check Details window of the Timber Design add-on displays design check UL7100 for the shear resistance of sheathing-to-beam connectors in the longitudinal direction, calculated according to NDS 2024 and SDPWS 2021. 
  • Timber design
  • NDS 2024
  • Shear wall
  • Design check
  • Allowable shear capacity
  • Wood structural panels
  • SDPWS 2021
  • Design ratio
  • Fastener design
Used in
  • 2021 SDPWS Wood Shear Wall Nonlinear Fastener Slip in RFEM 6