2026-08-12
064310
a) Endplate/Bolt, b) Stiffener Configuration
Technical drawing of an extended endplate connection showing bolt arrangement and stiffener configuration for steel joint analysis.
The diagram illustrates the geometry and component layout of an extended endplate connection specimen. Part (a) details the endplate and bolt configuration with dimensions for plate width, total height, and the positioning of six bolts. Part (b) shows the corresponding stiffener configuration with a height of 300 mm and a width of 150 mm.